PEPPOL-COMMON-R049 The Seller electronic address (BT-34) is "2021005488" under scheme "0007", which identifies the Swedish organisation number (Organisationsnummer)
The Seller electronic address (BT-34) is "2021005488" under scheme "0007", which identifies the Swedish organisation number (Organisationsnummer). A value in that scheme must be exactly ten digits ending in a Luhn check digit, and this one is not. Sweden's organisationsnummer is a ten-digit Luhn-checked value, written without the hyphen that Swedish paperwork usually shows. Strip the hyphen and keep all ten digits — dropping the century prefix is the common way to break it. Peppol flags this fatal: the identifier is what an access point resolves to find your counterparty, so a value that fails its own check digit is undeliverable. This is a Peppol BIS Billing 3.0 profile rule: it applies because profile is "peppol-bis-3". It does not apply to the en16931, xrechnung-ubl or xrechnung-cii profiles, whose validators will accept the same document.
This rule is implemented and its error payload below is real, but the long-form write-up — normative text, worked example, divergence note — is not written yet. Everything the library knows about this rule is on this page. Ask and we will prioritise it.
- Business term
BT-34- Severity
fatal
What the library returns
The exact object in result.errors when this rule fires.
Generated by running @attestwire/en16931, not transcribed:
{
"rule": "PEPPOL-COMMON-R049",
"field": "BT-34",
"severity": "fatal",
"message": "The Seller electronic address (BT-34) is \"2021005488\" under scheme \"0007\", which identifies the Swedish organisation number (Organisationsnummer). A value in that scheme must be exactly ten digits ending in a Luhn check digit, and this one is not. Sweden's organisationsnummer is a ten-digit Luhn-checked value, written without the hyphen that Swedish paperwork usually shows. Strip the hyphen and keep all ten digits — dropping the century prefix is the common way to break it. Peppol flags this fatal: the identifier is what an access point resolves to find your counterparty, so a value that fails its own check digit is undeliverable. This is a Peppol BIS Billing 3.0 profile rule: it applies because profile is \"peppol-bis-3\". It does not apply to the en16931, xrechnung-ubl or xrechnung-cii profiles, whose validators will accept the same document.",
"fix": "Correct seller.electronicAddress, or change its scheme identifier if the value belongs to a different register. A check digit failing almost always means one digit was transposed or dropped in transcription — compare it against the source register rather than re-typing it.",
"example": "\"electronicAddress\": { \"schemeId\": \"0007\", \"value\": \"2021005489\" }",
"xpath": "/ubl:Invoice/cac:AccountingSupplierParty/cac:Party/cbc:EndpointID",
"docsUrl": "https://attestwire.com/rules/PEPPOL-COMMON-R049"
}
xpath locates the element in the generated UBL document,
which is where a KoSIT or Peppol validator will report the same problem.
A passing value
"electronicAddress": { "schemeId": "0007", "value": "2021005489" }The fix
Correct seller.electronicAddress, or change its scheme identifier if the value belongs to a different register. A check digit failing almost always means one digit was transposed or dropped in transcription — compare it against the source register rather than re-typing it.